Posted in | News | Lab on a Chip | Nanofluidics

Novel Microfluidic Device Holds Promise as Low-Cost, Portable Malaria-Detection Device

Researchers at MIT have found a way to detect early-stage malarial infection of blood cells by measuring changes in the infected cells’ electrical properties.

The scientists, from the laboratories of MIT’s Anantha Chandrakasan and Subra Suresh — who is now president of Carnegie Mellon University — have built an experimental microfluidic device that takes a drop of blood and streams it across an electrode that measures a signal differentiating infected cells from uninfected cells. The work, published Aug. 8 in the journal Lab on a Chip, is a first step toward a field-ready, low-cost, portable malaria-detection device.

“Ultimately the goal would be to create a postage stamp-sized device with integrated electronics that can detect if a person has malaria and at what stage,” says Chandrakasan, the Joseph F. and Nancy P. Keithley Professor of Electrical Engineering and a principal investigator at MIT’s Microsystems Technology Laboratories (MTL), who specializes in developing low-power electronic devices. Similar diagnostics may be applicable to other infections and diseases.

Sorting out the signals

When the malaria parasite Plasmodium falciparum infects a red blood cell, the cell becomes more magnetic and more rigid, properties that can be detected in a rapid-diagnostic device. But these changes are hard to detect before the parasite matures beyond the ring stage — its earliest stage, and the only stage found in circulating blood. At later stages of infection, the infected red blood cells adhere to small capillaries, blocking circulation and causing various symptoms, and even death in severe cases.

So the researchers decided to look into using electrical impedance as a diagnostic signal. Several types of infection, including malaria, alter a cell’s impedance, a measure of electrical resistance across the cell membrane. Studies had already measured electrical changes in later-stage infected cells, but it wasn’t clear that cells that had reached only the ring stage of infection would exhibit electrical changes.

To find out, first authors Sungjae Ha, a graduate student in the Chandrakasan lab, and Sarah Du, a postdoc in the Suresh lab (also known as the Nanomechanics Laboratory), built a microfluidic device capable of measuring the magnitude and phase of the electrical impedance of individual cells. The device is essentially a cell-counting device, similar in approach to other low-cost, portable devices being developed to diagnose illnesses such as HIV.

The challenge, however, involved optimizing the electronics to allow very accurate measurements of impedance for each cell as it passes by. The researchers had to minimize interfering electric signals from the substrate the blood flows over and prevent the cells from sticking to one another.

In tests of cells of four cell types — uninfected cells and infected cells at the ring, trophozoite and schizont stages — the device detected small differences in measures of magnitude and seemingly random differences in phase, but not quite enough to definitively differentiate among stages.

However, by mathematically combining the measures into an index called delta, the differences between uninfected cells and all three stages became clear. “It’s much more significant,” says corresponding author Ming Dao, a principal research scientist in the Nanomechanics Laboratory. “It’s a more holistic approach. By using all of the information we can measure, we can detect the differentiating signals much more clearly.”

Solving real-world problems

Malaria is a curable disease, but diagnosis remains a challenge. This ability to discern the circulating parasite’s stage from a drop of blood opens the possibility of building a device that could be used to rapidly diagnose malarial infection in places where laboratories and skilled medical personnel are scarce.

Traditionally, technicians detect malarial infection visually, by observing blood smears through a microscope. More recently, the World Health Organization has supported the use of rapid diagnostic tests that detect an antigen to the parasite in the blood. These tests provide results in about 15 minutes and do not require skilled technicians, so sick people can be diagnosed and treated on the spot.

The collaborative MIT team of experts in microfluidics, circuit design, materials science and microbiology has designed their new cell-differentiating technology so that it can be packaged as a low-cost device, but more work needs to be done. “We are using our combined expertise to push the technology toward real-world applications,” Dao says.

The next steps for further development involve integrating this new technology into a small, low-cost package. “Our hope is that such technologies as those described in this work will ultimately help meet the need for a new generation of portable, disposable and inexpensive diagnostics for a variety of human diseases,” Suresh says.

The team is also interested in using the device to investigate the electrical properties of other types of diseased cells to see if electrical impedance changes could be used for diagnostics.

This work was carried out with the assistance of the Fulbright Science and Technology Award. Device fabrications were carried out at MTL. The work was supported by Singapore’s National Research Foundation through the Singapore-MIT Alliance for Research and Technology (SMART) and by SMART, MIT’s Center for Integrated Circuits and Systems and the National Institutes of Health.

Disclaimer: The views expressed here are those of the author expressed in their private capacity and do not necessarily represent the views of AZoM.com Limited T/A AZoNetwork the owner and operator of this website. This disclaimer forms part of the Terms and conditions of use of this website.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Massachusetts Institute of Technology. (2019, February 11). Novel Microfluidic Device Holds Promise as Low-Cost, Portable Malaria-Detection Device. AZoNano. Retrieved on November 21, 2024 from https://www.azonano.com/news.aspx?newsID=28058.

  • MLA

    Massachusetts Institute of Technology. "Novel Microfluidic Device Holds Promise as Low-Cost, Portable Malaria-Detection Device". AZoNano. 21 November 2024. <https://www.azonano.com/news.aspx?newsID=28058>.

  • Chicago

    Massachusetts Institute of Technology. "Novel Microfluidic Device Holds Promise as Low-Cost, Portable Malaria-Detection Device". AZoNano. https://www.azonano.com/news.aspx?newsID=28058. (accessed November 21, 2024).

  • Harvard

    Massachusetts Institute of Technology. 2019. Novel Microfluidic Device Holds Promise as Low-Cost, Portable Malaria-Detection Device. AZoNano, viewed 21 November 2024, https://www.azonano.com/news.aspx?newsID=28058.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this news story?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.