Smart & Safe Microwave Digestion with the Multiwave 5001 and Multiwave 3001

With more than 50 years of experience in sample preparation, Anton Paar has created a microwave digestion system that can meet every requirement. Multiwave 5001 and Multiwave 3001 are solutions for all types of throughput or application needs, including battery materials, environmental samples, food and feed produce, chemicals, and drugs, as well as normal and extremely demanding samples.

Highest temperatures allow for the quick and effective digestion of difficult materials. Tool-free vessel and rotor handling increases throughput and reduces digestion expenses by opening and closing vessels twice as quickly. Featuring a “clever” door, recipes, full-text method search, and 600 pre-installed programs, Multiwave 5001 and Multiwave 3001 guarantee efficient operation.

Multiwave 5001

Smart & Safe Microwave Digestion with the Multiwave 5001

Image Credit: Anton Paar GmbH

  • One microwave digestion system that can be used for any purpose
  • SmartVent-enabled vessels manage overpressure
  • Premium digestion parameters – up to 300 °C and 100 bar
  • Smart sensors for dependable, consistent results
  • Safety features that are certified to keep operators safe

Multiwave 3001

Smart & Safe Microwave Digestion with the Multiwave 5001

Image Credit: Anton Paar GmbH

  • An excellent microwave digestion system in terms of cost-effectiveness
  • Effective digestion of standard samples
  • SmartVent-enabled vessels manage overpressure
  • Increase productivity through tool-free, quick, and safe vessel operation
  • Safety features that are certified to keep operators safe

Key Features

Smart & Safe Microwave Digestion with the Multiwave 5001

Image Credit: Anton Paar GmbH

These microwave digestion systems combine decades of experience in sample preparation and microwave digestion, ensuring dependability and precision with each run. Regardless of the future, they ensure that the sample is properly prepared for trace metal analysis.

Multiwave 5001 is ready for any application, from acid digestion to extraction. Expect the highest throughput and temperatures. Multiwave 5001 is equipped with SmartTemp 2.0, the most recent version of accurate and stable temperature measurement, ensuring best-in-class repeatability and consistency.

Multiwave 3001 is the most cost-effective and versatile solution for most applications.

Empowered By Smart Technology

Smart & Safe Microwave Digestion with the Multiwave 5001

Image Credit: Anton Paar GmbH

Say goodbye to tedious chores with Multiwave 5001 and Multiwave 3001, and let the software, integrated guidelines, and simplified design take care of things for the users. These devices consistently produce crystal-clear findings and have the largest sample throughput of up to 64 vessels in a single run.

Clever features such as vessels equipped with SmartVent technology, tool-free operation, optimized workflows, and the widest selection of rotors and accessories make handling easier. Since overpressure is securely released, users can obtain peak digestion temperatures with Multiwave instruments regardless of sample size.

Fully Connected, 24/7

Smart & Safe Microwave Digestion with the Multiwave 5001

Image Credit: Anton Paar GmbH

Stay one step ahead of digital transformation with the Multiwave 5001 and 3001. The results are traceable, fulfilling the most stringent industry requirements and regulations.

Thanks to the integration of Anton Paar Connect (Multiwave 5001) and automated data export, users can easily access their data and share the results with third parties. SmartLink enables users to monitor and control the experiment from any device.

Vast Application Knowledge Informs World-Class Support

Smart & Safe Microwave Digestion with the Multiwave 5001

Image Credit: Anton Paar GmbH

With Multiwave 5001 and Multiwave 3001, users can benefit from Anton Paar's decades of microwave digestion expertise, available through global application support. Users are guided every step of the way thanks to easy features and application expertise, such as the integrated keyword search, the largest method library (600+ techniques), and the most extensive video guides. Furthermore, Anton Paar is the only provider that allows users to acquire accessories and consumables quickly and at any time through their webshop.

Certified Safety and Warranted Quality

Smart & Safe Microwave Digestion with the Multiwave 5001

Image Credit: Anton Paar GmbH

Multiwave 5001 and Multiwave 3001 were designed with world-class quality in mind. They have several features that assure total safety and overall build robustness. An optional camera for Multiwave 5001 provides additional operational insights. Multiwave 5001 is the only microwave digesting equipment that is ETL and GS-certified.

Due to the great quality of the instruments, Anton Paar is pleased to provide a three-year warranty to all clients as standard. This makes Multiwave 5001 and Multiwave 3001 unsurpassed in terms of durability and safety.

One Microwave Digestion Platform for Every Application

Smart & Safe Microwave Digestion with the Multiwave 5001

Image Credit: Anton Paar GmbH

Multiwave 5001 and Multiwave 3001 use acid digestion and leaching to prepare samples for environmental analysis, food testing, and pharmaceutical research, respectively.

Multiwave 5001 can accomplish even more. It works with a variety of sample preparation procedures, including:

  • Solvent extraction
  • Evaporation
  • Sample drying
  • Synthesis

These are faster, safer, cleaner, and more cost-effective than conventional conventionally heated alternatives.

Technical Specifications

Source: Anton Paar GmbH

The primary acid digestion rotors of Multiwave 50011 and 3001: 

  Rotor 24HVT Rotor 41HVT Rotor 20SVT Rotor 8 NXF Rotor 64MG5
Number of vessels 24 41 20 8 64
Volume 50 mL/80 mL 56 mL 50 mL 100 mL 5 mL
Material PTFE-TFM PTFE-TFM PTFE-TFM PTFE-TFM Glass
HF resistance Yes Yes Yes Yes No
Temperature control Internal T in all positions / SmartTemp 2.02 SmartTemp 2.02 T in all positions IR in 16 positions
Pressure control SmartVent technology / SmartVent detection p in all vessels PTFE seal
Applications Routine samples: Biological and environmental samples, EPA procedures, food, cosmetic and pharmaceutical samples Harder to digest samples: including polymers, ceramics, petroleum products, and alloys Most difficult samples Micro samples up to 20 mg
Compatible with Multiwave 3001, Multiwave 5001 Multiwave 5001 Multiwave 5001 Multiwave 5001

1Multiwave 5001 is backwards compatible, it can accommodate Rotor 16 and accessories of older Multiwave models.
²Multiwave 5001 only

Other Equipment by this Supplier

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.