DCG Systems Debuts Meridian M for Static Optical Failure Analysis

DCG Systems® today announced the release of the Meridian M™ system for isolation of routine and challenging electrical faults at the wafer level.

Meridian M emission image from 22nm SOI test chip

Offering photon emission for transistor-level defects and leakage, and a complete portfolio of static laser stimulation techniques for metallization defects, the Meridian M system is a critical tool to support production use cases in memory and foundry failure analysis (FA) labs. Its high sensitivity, extended-wavelength DBX™ optics capture even the most challenging faults, including:

  • Large-area process variation in advanced memory devices that can lead to anomalous leakage;
  • High resistivity wordline to wordline or bitline to bitline shorts within memory cells;
  • Resistive faults in low voltage GPUs and other low-voltage logic circuits; and
  • Any weakly emitting faults requiring long integration time.

The Meridian M system also captures electrical faults that emit photons primarily in the thermal range (>1850nm), such as partial opens, high-ohmic shorts and electromigration.

"Static optical fault isolation (OFI) is in a renaissance," said Praveen Vedagarbha, Ph.D., business unit manager of the Meridian product group at DCG Systems. "While dynamic OFI is important for localizing parametric faults, static OFI is faster and easier to use than its dynamic counterpart because it does not require docking to a tester or having the device and tester knowledge necessary to edit the test program. The speed and ease of use of the Meridian M system are particularly valuable in early yield ramp, when rapid feedback to the process engineering team is critical."

Among static-only optical fault isolation systems, Meridian M has demonstrated superior performance in localizing faults with the weakest photon emission. Custom-designed optics, a set of user-selectable wavelength ranges, and the lowest background noise in the industry allow Meridian M to be optimized for a variety of fault types, from conventional "optical" emitters such as excessive leakage, saturation and latch-up faults to longer-wavelength "thermal" emitters, such as high-resistance shorts and dopant displacement errors. Because it accommodates full wafers in addition to packaged die, the Meridian M system allows comparison of good die to bad die, aiding interpretation of complex thermal and photon emission images.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this news story?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.