Liver-on-Chip Device with Nanotechnology-Based Optoelectronic Sensors Mimicks Human Physiology

Safety evaluation is a critical part of drug and cosmetic development. In recent years there has been a growing understanding that animal experiments fail to predict the human response, necessitating the development of alternative models to predict drug toxicity.

Nanotechnology-Based Optoelectronic Sensors Mimicks Human Physiology" />
This image shows the Hebrew University liver-on-chip device. Photo credit: Yaakov Nahmias / Hebrew University

The recent tightening of European regulations preventing the cosmetic industry from using animals in research and development, blocks companies like L'Oréal and Estée Lauder from developing new products, bringing massive investment into this field.

The main challenge in replacing animal experiments is that human cells seldom survive more than a few days outside the body. To address this challenge, scientists at the Hebrew University of Jerusalem and the Fraunhofer Institute for Cell Therapy and Immunology in Germany partnered to create a liver-on-chip device mimicking human physiology.

"The liver organs we created were less than a millimeter in diameter and survive for more than a month," said Prof. Yaakov Nahmias, the study's lead author and Director of the Alexander Grass Center for Bioengineering at the Hebrew University.

While other groups showed similar results, the breakthrough came when the groups added nanotechnology-based sensors to the mix. "We realized that because we are building the organs ourselves, we are not limited to biology, and could introduce electronic and optical sensors to the tissue itself. Essentially we are building bionic organs on a chip," said Nahmias.

The addition of nanotechnology-based optoelectronic sensors to the living tissues enabled the group to identify a new mechanism of acetaminophen (Tylenol) toxicity.

"Because we placed sensors inside the tissue, we could detect small and fast changes in cellular respiration that nobody else could," said Nahmias.

The authors discovered that acetaminophen blocked respiration, much faster and at a much lower dose than previously believed. The current understanding was that acetaminophen was broken to a toxic compound, called NAPQI, before damaging the cells. As the liver could naturally deactivate NAPQI, damage was thought to occur only at high doses and in cases of diseased or compromised liver function.

The current study, released online in the leading journal Archives of Toxicology, turns 50 years of research on its head. The authors found that acetaminophen itself can stop cellular respiration in minutes, even in the absence of NAPQI, explaining much of the off target effects of the drugs.

"This is a fascinating study," said Prof. Oren Shibolet, Head of the Liver Unit at the Tel-Aviv Sourasky Medical Center, and one of the leading experts on drug-induced liver injury, who was not involved in the original study. "We knew that acetaminophen can cause nephrotoxicity as well as rare but serious skin reactions, but up until now, we didn't really understand the mechanism of such an effect. This new technology provides exceptional insight into drug toxicity, and could in fact transform current practice."

The results mark the first discovery of a new toxicity mechanism using the newly emerging human-on-a-chip technology, suggesting that the development of alternative models for animal testing is just around the corner. The global market of this technology is estimated to grow to $17 billion by 2018, showing a double-digit annual growth rate in the last three years.

Yissum, the Research and Development Company of the Hebrew University, together with the Fraunhofer Institute for Cell Therapy and Immunology (IZI-BB) in Germany submitted a joint provisional patent application earlier this year and are actively seeking industrial partners.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this news story?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.